We found results for “”
CVE-2022-33742
Date: July 5, 2022
Linux disk/nic frontends data leaks T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Linux Block and Network PV device frontends don't zero memory regions before sharing them with the backend (CVE-2022-26365, CVE-2022-33740). Additionally the granularity of the grant table doesn't allow sharing less than a 4K page, leading to unrelated data residing in the same 4K page as data shared with a backend being accessible by such backend (CVE-2022-33741, CVE-2022-33742).
Severity Score
Related Resources (14)
Severity Score
Weakness Type (CWE)
Exposure of Sensitive Information to an Unauthorized Actor
CWE-200CVSS v3.1
| Base Score: |
|
|---|---|
| Attack Vector (AV): | LOCAL |
| Attack Complexity (AC): | LOW |
| Privileges Required (PR): | LOW |
| User Interaction (UI): | NONE |
| Scope (S): | UNCHANGED |
| Confidentiality (C): | HIGH |
| Integrity (I): | NONE |
| Availability (A): | HIGH |
CVSS v2
| Base Score: |
|
|---|---|
| Access Vector (AV): | LOCAL |
| Access Complexity (AC): | LOW |
| Authentication (AU): | NONE |
| Confidentiality (C): | PARTIAL |
| Integrity (I): | NONE |
| Availability (A): | PARTIAL |
| Additional information: |
Vulnerabilities
Projects
Contact Us