CVE-2026-84712
Published:September 23, 2026
Updated:October 11, 2026
A flaw was found in the automation-controller API. The
unauthenticated health-check endpoint /api/v2/ping/
(ApiV2PingView, AllowAny) over-serializes RBAC-gated
automation-mesh data into its anonymous response, exposing the
full instance inventory (node hostnames, node types, UUIDs,
heartbeats, capacities, and exact versions), all instance-group
names and membership, the deployment install UUID, and the
active control node. A remote, unauthenticated attacker can use
this to map the control plane and fingerprint software versions
for targeted attacks. This flaw affects confidentiality only;
it does not expose secrets, credentials, or tenant data.
Related Resources (6)
Do you need more information?
Contact UsCVSS v4
Base Score:
6.9
Attack Vector
NETWORK
Attack Complexity
LOW
Attack Requirements
NONE
Privileges Required
NONE
User Interaction
NONE
Vulnerable System Confidentiality
LOW
Vulnerable System Integrity
NONE
Vulnerable System Availability
NONE
Subsequent System Confidentiality
NONE
Subsequent System Integrity
NONE
Subsequent System Availability
NONE